贵阳电梯安装公司告诉你如今消防电梯存在的问题;
Guiyang elevator installation company tells you the problems existing in the fire elevator.
消防电梯是在建筑物发生火灾时供消防人员进行灭火与救援使用且具有一定功能的电梯。因此,消防电梯具有较高的防火要求,其防火设计十分重要。据有关部门统计,近五年,国内发生火灾近120万起,火灾造成12268人死亡、15757人受伤,直接财产损失达75.6亿元。那么,如今的消防电梯究竟还存在哪些问题呢?
Fire elevator is an elevator for fire fighting and rescue use and has a certain function in the case of a building fire. Therefore, the fire elevator has high fire protection requirements, and its fire protection design is very important. According to the statistics of relevant departments, nearly five years in China, nearly 1 million 200 thousand fires have occurred in China. 12268 people have been killed and 15757 people have been injured, and the loss of direct property has reached 7 billion 560 million yuan. So, what are the problems that still exist in the fire elevator?
《建筑设计防火规范》、《消防电梯制造与安装安全规范》、《电梯制造与安装安全规范》中均对高层建筑物内消防电梯的设置和使用提出了具体的规定。但是目前许多建筑物内消防(员)电梯的设置极不规范,随意性太大。
In the code for fire protection design of buildings, safety code for manufacture and installation of fire elevators and safety code for manufacture and installation of elevators, specific provisions for the setting and use of fire elevators in high-rise buildings are put forward. But at present, in many buildings, the setting of the elevator is very irregularities and is too random.
按照《建筑设计防火规范》规定,一类公共建筑、塔式住宅、十二层以上的单元式住宅或通廊式住宅、高度超过32米的其它二类公共建筑均应设置消防电梯。其数量为当每层建筑面积不大于1500平方米时,应设1台;当大于1500平方米但不大于4500平方米时,应设2台;当大于4500平方米时,应设3台,以此类推。
According to the provisions of the "standard" fire protection design of buildings, the other two types of public buildings for a class of public buildings, residential tower, apartment or corridor style residential, twelve floors above the height of over 32 meters shall be provided with fire elevator. The number is when each floor area of not more than 1500 square meters, 1 units should be set up; when more than 1500 square meters but not more than 4500 square meters, 2 units should be set up; when more than 4500 square meters, should be set to 3, and so on.
目前,消防电梯还通常和普通电梯设置在同一个候梯厅内,缺乏进入电梯的前室,一旦发生火灾时无法阻止火势向电梯漫延,这种做法是不对的。
At present, the fire elevator and ordinary elevator is usually arranged in the same waiting hall, lack of access to the elevator front room, unable to prevent the fire from spreading to the elevator in case of fire, this practice is wrong.
许多大楼在消防电梯的设置上没有符合上述规范要求,同国家标准要求差距甚大,存在严重威胁大楼内人员安全的隐患,这是应该引起重视和采取补救措施……对消防电梯消防功能理解有误在电梯采购时,为节省采购费用和对电梯消防功能理解有误或受个别人的误导,而将“迫降功能”误当消防功能订购造成后期使用中留下安全隐患。
Many buildings fail to meet the above requirements in the setting of fire elevators, which are quite different from the national standards. There is a serious threat to the safety of personnel in buildings. This is a cause for attention and remedial measures. The function of fire elevator is erroneously understood. During the elevator purchase, the "forced landing function" is mistaken for the fire function order to save cost and misunderstand the elevator fire function, or to be misled by others.
消防电梯的使用功能规定,消防电梯应当在设在电梯基站的消防开关合上后,该台电梯立刻进入消防工作状态,此时电梯不论处于何种位置、何种状态该电梯均应立即直接驶向基站,这就是电梯的“迫降功能”。此刻,电梯的内呼、外召按钮开关均失效不再作响应,电梯到达基站后立即开门,原巳登记的呼梯信号也自动消号,门的光电保护和安全触板也均不起作用。
The use of functional requirements of fire elevator, fire elevator should be in the fire station on the elevator switch is arranged after the elevator immediately entered the state fire control work, the elevator at any position, what state the elevator shall immediately directly to the base station, which is the function of elevator landing". At the moment, the internal call and external call button switches of the elevator are both invalid and no longer respond. The elevator opens immediately after reaching the base station, and the original registered call signal is also automatically eliminated, and the photoelectric protection and safety touchpad of the door do not work.
届时,消防救助人员可持有关救援工具迅速进入电梯轿厢并立即前去火灾楼层营救、灭火。此时,电梯已不具备自动应答功能,只响应轿厢内选登记信号,并在应答第一个信号后,其余内选信号将自动消号,到达所选楼层前不能自动开门,须按动开门按钮轿门才能开启。而且,在轿门未完全开启之前,一旦松手轿门又会重新关闭。在轿门完全开启情况下,轿门可保持开启状态,只有按住关门按钮才能关门,此时电梯已由自动操作转变为有司机人控操作。这才是消防电梯真正完整的“消防功能”,“迫降功能”只是消防电梯的部分功能,而不是其全部功能,切不可二者误解。
At that time, the fire rescuers can quickly enter the elevator car with relevant rescue tools and immediately go to the fire floor to rescue and extinguish the fire. At this point, the elevator does not have the automatic response function. Only when responding to the selection signal in the car, and after answering the first signal, the rest of the selected signals will automatically disappear. Before the floor is selected, it can't open the door automatically, and the door must be pressed to open the door. Moreover, the sedan door will be closed again once the door is not fully opened. When the car door is fully open, the door can remain open. Only by holding the closing button can the door be closed. At this time, the elevator has been changed from automatic operation to manned operation. This is the real integrity function of fire elevator, and the function of "forced landing" is only part of the function of fire elevator, rather than all its functions, so we must not misunderstand the two.
原《电梯监督检验规程》对电梯消防功能的检验欠完善原《电梯监督检验规程》中对电梯消防功能的检验只要求检验其“迫降功能”,而“迫降”后消防人员进入轿厢后的救援操作功能欠完善,此时,电梯随时可被外部呼梯招唤而影响消防人员的救援工作。这种检验也不符合设计规范对电梯消防功能的要求,呼吁加检后续功能。
Test of the original "elevator supervision and inspection rules" to lift fire function is not perfect the original "elevator supervision and inspection rules" in the inspection of the fire lift function requires only test the "landing function", "landing" after the firefighters entered the car after the rescue operation function is not perfect, at this time, the elevator can be external call at any time call of Ladder Fire Rescue work. This inspection does not conform to the requirements of the design specification for the elevator fire protection, and calls for the follow-up function.